Avg Home: 8–12 GPM | Homestead: 15–20 GPM
ft
Dynamic water level + drop to pump setting
ft
Vertical climb from wellhead to pressure tank
ft
Trench length from wellhead to house
RECOMMENDED PUMP MOTOR 1.5 HP (1-1/2 HP) 1.11 HP (Shaft Load)
TOTAL DYNAMIC HEAD (TDH) 256 ft Head 2.6 ft Friction Loss
CABLE WIRE GAUGE 14 AWG Copper
BREAKER SIZE 25A (2-Pole)
MIN PRESSURE TANK 37+ Gal Tank
💧 Pressure Tank Drawdown Capacity:

Min 10 Gal Drawdown (provides safe 60s motor cycle)

Deep Well Submersible Pumping System Blueprint

Cross-sectional engineering diagram: Well casing, dynamic water level, submersible pump, pitless adapter, and residential pressure tank assembly.

TDH: 256 ft Head
Drilled Well & Submersible Pump Cross-Section Hydraulic blueprint illustrating deep well casing, submersible motor, drop pipe, pitless adapter, buried waterline, and indoor pressure tank. GRADE LEVEL (SURFACE) WATER LEVEL (100′) WELL SEAL 1.25″ Water Line PUMP MOTOR UTILITY ROOM / TANK 60 PSI HOME ▶ PRESSURE TANK OPERATING POINT 10 GPM @ 1.5 HP (1-1/2 HP) TDH: 256 ft Head

Standard Engineering Benchmarks (100-Foot Setting)

Estimated Total Dynamic Head (TDH): ~245 ft Head (at 40/60 PSI shutoff)
Recommended Drop Pipe: 1.25″ 160 PSI NSF Polyethylene (PE)
Drop Cable Requirement: 14 AWG Copper (2-wire)
Control Box Requirement: 2-Wire System (No external control box needed)
Recommended Pressure Tank: 20 to 32 Gallons (e.g., WX-202)
Safety Rope Break Rating: 300 lbs minimum rating

Hydraulic Engineering Profile: 100-Foot Water Well

A 100-foot well is the sweet spot for economical 2-wire installations. Because hydrostatic backpressure is only 43 PSI at rest, standard 160 PSI poly pipe offers an exceptional 3.7x safety margin. No intermediate check valves are needed, and an expensive control box can be safely omitted.

⚡ Physical Weight & Pressure Metrics at 100 ft Depth:
  • Hydrostatic Water Column Weight: ~65 lbs resting inside the drop pipe.
  • Pump & Motor Assembly Weight: ~35 lbs (stainless steel pump wet-end + motor).
  • Total Static Suspended Load: ~100 lbs pulling down on the pitless adapter.
  • Static Hydrostatic Backpressure: 43 PSI pressing against the check valve.
  • Impeller Staging Required: 7 to 9 Floating Thermoplastic (Noryl) Stages.
  • Recommended Pulling Rig: Manual Hand-Pullable (2 Able-Bodied Adults with Pipe Clamps).

Proven Submersible Pump Models for 100 Feet

Contractors do not buy generic horsepower ratings; they match manufacturer pump curves against Total Dynamic Head. The following commercial pump wet-ends are engineered for 100-foot head requirements:

  • Goulds Water Technology 10GS07 (10 GPM, 3/4 HP)
  • Grundfos 10S07-9 (10 GPM, 9-Stage)
  • Franklin Electric 10G07S4-PE (3/4 HP, 2-Wire)

Complete Installation Bill of Materials (100 ft Well)

A complete contractor hardware shopping list for installing a pump at this depth:

Quantity Hardware Specification for 100 Feet
100 ft 1-1/4″ 160 PSI SIDR-11.5 NSF-certified Polyethylene Pipe
115 ft 14/2 Submersible Copper Flat Wire with Ground
1 × 1-1/4″ Stainless Steel Barbed Insert Male Terminal Adapter
4 × 100% Marine Grade 300-Series All-Stainless Hose Clamps
100 ft 1/4″ Braided Polypropylene Safety Rope (300 lb min break strength)
1 × 1-1/4″ Lead-Free Bronze Spring-Loaded Discharge Check Valve

Primary Failure Mode at 100 Feet

⚠️ Common Field Breakdown:

Over-pumping shallow aquifers: 100-ft wells frequently experience seasonal recovery drop-offs during dry summer months. Installing an oversized 15 GPM pump aerates the casing and burns dry-run bearings.

Check Valve Staging & Water Hammer Prevention

Under Franklin Electric and National Ground Water Association (NGWA) standards, check valves must never be spaced more than 200 feet apart:

Check Valves Mandated: 1 Valve Required
Placement Configuration: 1 spring-loaded internal check valve directly at the pump discharge head